Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(2): e54340, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38500947

RESUMO

Background and objective Human teeth have a significant forensic importance. As they are the hardest of all human tissues, they are not just chemically stable but also their characteristics are maintained for a long time after death even in the most harsh environmental conditions. Despite the advances made in DNA analysis, fingerprinting, etc., ABO blood grouping still plays a significant role in the forensic practice in the field of personal identification, paternity disputes, and several other scenarios including the identification of mass disaster victims. The term blood groups refers to inherited antigens on the surface of red blood cells (RBCs) detected by specific antibodies. Since tooth pulp contains numerous blood vessels, blood group antigens are most certainly bound to be present in tooth pulp. Various studies have shown that blood group antigens in the pulp and dentin are preserved as long as up to two years after the demise of an individual. Absorption-elution technique has been proven to be the most sensitive, reliable, and consistent method to determine the ABO blood group from both the pulp and dentine. This study aimed to ascertain the ABO blood group from both the hard (dentin) as well as the soft tissue (pulp) of the tooth by using the absorption-elution (AE) technique and also to determine if there are any variations in identifying the blood groups from the teeth based on age and gender. Material and methods After obtaining due consent, we included patients of both genders aged between 16-60 years visiting the outpatient department (OPD) clinics at the College of Dentistry for periodontal or orthodontic extractions. One patient's blood type was determined by using the slide agglutination technique before any capillary blood extraction was performed; this patient served as a control. For this investigation, we used the pulp and powdered dentin samples taken from the dental extractions to test for the presence of ABO and Rhesus (Rh) factor antigens by using the AE method. The study samples were compared with the control for blood group determination. Statistical analysis was carried out using the chi-square test with Monte Carlo (MC) simulation to check for any correlation of blood grouping with age and gender. Results The dentin and pulp were shown to have positive blood group antigens for the ABO and Rh factors. While neither pulp nor dentin performed significantly differently in identifying the blood group antigens, pulp showed marginally higher accuracy. There was no discernible difference regarding gender or age in the dentin or pulp of any of the 45 samples studied. Conclusions For determining an individual's blood type and Rh factor, both the hard (dentin) and soft (pulp) tissues of a tooth are valid sources. This is particularly helpful in forensic medicine cases where teeth are the only remains that can be viably used to find out a person's identity.

2.
J Infect Public Health ; 16(11): 1769-1772, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37741012

RESUMO

BACKGROUND: Surveillance data are very essential for the effective use of available resources, the prioritization of infection control practices, and setting goals for intervention. The aim was to present the current rates of healthcare-associated infections (HAIs) and device utilization ratios (DUR) among the Saudi Ministry of health (MOH) hospitals. METHODS: MOH analyzed the surveillance data collected from 106 MOH hospitals enrolled in the health electronic surveillance network (HESN) between January 2022 and December 2022. The surveillance methodology was similar to the methods of the US National Healthcare Safety Network (NHSN) and the Gulf Cooperation Council (GCC) center for infection control. RESULTS: More than one million device-days of surveillance were analyzed. The rate of central line associated bloodstream infection (CLABSI) was 2.57 per 1000 central lines days. The rate of catheter-associated urinary tract infection (CAUTI) was 1.08 per 1000 urinary catheter days. The rate of ventilator-associated events (VAE) was 4.21 per 1000 ventilator days. The average rate of pediatric/neonatal ventilator-associated pneumonia (VAP) was 1.53 per 1000 ventilator days. The average DURs were 0.33 for central line, 0.61 for urinary catheter, 0.44 for ventilator in adult patients, and 0.26 in ventilator in pediatric/neonatal patients. In 238632 months of surveillance, the rate of dialysis events (DE) was 0.97 per 100 patient-months. In 86324 surgeries monitored, the rate of surgical site infection (SSI) was 0.87 per 100 surgeries surveyed. CONCLUSIONS: The current report can serve as a national benchmark for MOH hospitals and a regional benchmark for similar hospitals in the region.

3.
Am J Infect Control ; 51(10): 1108-1113, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37024013

RESUMO

BACKGROUND: COVID-19 is believed to increase the risk of secondary health care...associated infections. The objective was to estimate the impact of COVID-l9 pandemic on the rates of central line...associated bloodstream infection (CLABSI) and catheter-associated urinary tract infections (CAUTIs) in the.ßMinistry of Health hospitals across Saudi Arabia. METHODS: A retrospective analysis of prospectively collected CLABSI and CAUTI data over a period of 3 years (2019-2021) was done. The data were obtained from the Saudi Health Electronic Surveillance Network. All adult intensive care units in 78 Ministry of Health hospitals that contributed CLABSI or CAUTI data before (2019) and during (2020-2021).ßthe pandemic were included. RESULTS: During the study, 1440 CLABSI events and 1119 CAUTI events were identified. CLABSI rates significantly increased in 2020-2021 compared with 2019 (2.50 versus 2.16 per 1000 central line days, P.ß=.ß.010). CAUTI rates significantly decreased in 2020-2021 compared with 2019 (0.96 versus 1.54 per 1000 urinary catheter days, P.ß<.ß.001). CONCLUSIONS: COVID-19 pandemic is.ßassociated with increased CLABSI rates and reduced CAUTI rates. It.ßis believed to have negative impacts on several infection control practices and surveillance accuracy. The opposite impacts of COVID-19 on CLABSI and CAUTI probably reflect.ßthe nature of their case definitions.


Assuntos
COVID-19 , Infecções Relacionadas a Cateter , Cateteres Venosos Centrais , Infecção Hospitalar , Pneumonia Associada à Ventilação Mecânica , Sepse , Infecções Urinárias , Adulto , Humanos , Infecções Relacionadas a Cateter/epidemiologia , Pandemias , Estudos Retrospectivos , Pneumonia Associada à Ventilação Mecânica/epidemiologia , COVID-19/epidemiologia , Infecção Hospitalar/epidemiologia , Unidades de Terapia Intensiva , Infecções Urinárias/epidemiologia , Sepse/epidemiologia
4.
Life Sci ; 277: 119625, 2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-34015288

RESUMO

AIM: Iron oxide nanoparticles (IONPs) have been widely used in diagnosis, drug delivery, and therapy. However, the biodistribution and toxicity profile of IONPs remain debatable and incomplete, thus limiting their further use. We predict that coating iron oxide nanoparticles using curcumin (Cur-IONPs) will provide an advantage for their safety profile. MATERIALS AND METHODS: In this study, an evaluation of the multidose effect (6 doses of 5 mg/kg Cur-IONPs to male BALB/c mice, on alternating days for two weeks) on the toxicity and biodistribution of Cur-IONPs was conducted. KEY FINDINGS: Serum biochemical analysis demonstrated no significant difference in enzyme levels in the liver and kidney between the Cur-IONP-treated and control groups. Blood glucose level measurements showed a nonsignificant change between groups. However, the serum iron concentration was found to initially increase significantly but then decreased at 10 days after the final injection. Histopathological examination of the liver, spleen, kidneys, and brain showed no abnormalities or differences between the Cur-IONP-treated and control groups. There were no abnormal changes in mouse body weight. The biodistribution results showed that Cur-IONPs accumulated mainly in the liver, spleen, and brain, while almost no Cur-IONPs were found in the kidney. The iron content in the liver remained high even 10 days after the final injection, while the iron content in the spleen and brain had returned to normal levels by this time point, indicating their complete clearance. SIGNIFICANCE: These results are significant and promising for the further application of Cur-IONPs as theragnostic nanoparticles.


Assuntos
Curcumina/administração & dosagem , Curcumina/farmacologia , Nanopartículas Magnéticas de Óxido de Ferro/administração & dosagem , Animais , Encéfalo/efeitos dos fármacos , Curcumina/toxicidade , Compostos Férricos/farmacologia , Ferro/metabolismo , Rim/efeitos dos fármacos , Fígado/efeitos dos fármacos , Nanopartículas Magnéticas de Óxido de Ferro/química , Nanopartículas de Magnetita/química , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Nanopartículas/química , Baço/efeitos dos fármacos , Distribuição Tecidual/efeitos dos fármacos , Distribuição Tecidual/fisiologia
5.
Life Sci ; 230: 76-83, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31128136

RESUMO

AIM: In this study, in vivo biodistribution, clearness and toxicity of curcumin capped iron oxide nanoparticles (Cur-IONPs) were addressed in different body organs. MATERIALS AND METHODS: The physicochemical properties of the prepared Cur-IONPs were investigated. Long term (3 weeks) biodistribution, clearness and toxicity were assessed for a single-dose administration of Cur-IONPs (5 mg/kg). The iron content in liver, kidney, spleen and brain was quantified using atomic absorption spectroscopy. Serum biochemical parameters were also measured. KEY FINDINGS: The integrated in vivo results demonstrated that Cur-IONPs was mostly taken up in the liver and spleen reaching its highest levels on days 1 and 2, respectively. In the brain, the results showed significant accumulation of Cur-IONPs between 1 h to 1-day post injection. This represented the successful penetration Cur-IONPs across the blood-brain barrier. Serum biochemical analysis demonstrated a temporal disturbance in the performance of body organs. Also, the body weights showed no alteration throughout the experiment. SIGNIFICANCE: It has been deduced that the promising green synthesized Cur-IONPs as an "All in One" nanoplatform is safe enough to be used in diagnostic and therapeutic purposes.


Assuntos
Curcumina/metabolismo , Curcumina/farmacologia , Nanopartículas Metálicas/administração & dosagem , Animais , Encéfalo/efeitos dos fármacos , Curcumina/toxicidade , Compostos Férricos/metabolismo , Compostos Férricos/farmacologia , Ferro/metabolismo , Rim/efeitos dos fármacos , Fígado/efeitos dos fármacos , Masculino , Nanopartículas Metálicas/uso terapêutico , Camundongos , Camundongos Endogâmicos BALB C , Baço/efeitos dos fármacos , Distribuição Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...